13
OPERATION
INSTALLATION
Before rst use
● carefully clean the ceramic plate treating it as a glass surface,
● when used for the rst time the plate can give off a bit of a smell so switch on the ventilation
system or open the window,
● operate the plate observing the safety instructions.
DIAGRAM OF POSSIBLE CONNECTIONS
Important! Heating elements voltage 230V
Recom-
mended
type of
connector
cable
1 For 230 V power supply single
phase connection with a neutral
lead, 1-2 terminals are shorted
together , neutral lead connected
to 4, PE (protective earth) lead
connected to
1N~
H05VV-F
or
H05RR-F
3X 4 mm
2
2* For 400/230 V power supply
2-phase connection with a neu-
tral lead, neutral lead connected
to 4, PE (protective earth) lead
connected to
2N~
H05VV-F
or
H05RR-F
4X 2,5 mm
2
L1=R, L2=S, L3=T, N=neutral lead terminal , =PE lead terminal
* Connect the remaining wire to clamp 3 (connected to the cooker’s internal system) if
the mains power supply is a 3-phase 400/230V current.
Warning! In every type of connec-
tion protective grounding has to be
connected to terminal